Battery Charger ( BAC25A)

Battery charger BAC25A is a portable universal battery charger. It can be used for charging Lead-Acid and Ni-Cd batteries. BAC25A is intended to support the main charger in order to charge battery much faster. They can also be used to quickly recharge a battery following a discharge test . Using two charging modes it provides the safely regulation of charging procedure. As a result achieving both fast recharge and low risk of overcharge. This device generates current up to 25 A.

In addition, it is equipped with thermal, overcurrent, and over-voltage or under voltage protection. Provided display enables users to read all relevant information during a charging process and to adjust the charging current, charging time, etc.

BAC25A
BAC25A
BXL SERIES ( BXL-A)

  • designed for parallel operation with BLU-A series
  • applicable to 5,25 V – 300 V DC battery systems
  • weight – 12,5 kg (28 lbs.)
  • discharge power – up to 25,4 kW
  • discharge current – up to 250 A

BXL SERIES ( BXL-T)

  • designed for parallel operation with BLU-T series
  • applicable to 5,25 V – 70,5 V DC battery systems
  • weight – 12,5 kg (28 lbs.)
  • discharge power – up to 17,5 kW
  • discharge current – up to 310 A

BXL SERIES ( BXL-V)

  • designed for parallel operation with BLU360V
  • applicable to 5,25 V – 500 V DC battery systems
  • weight – 16 kg (35 lbs.)
  • discharge power – up to 35 kW
  • discharge current – up to 190 A

 
BXL-V
BXL-V
BXL-T
BXL-T
BXL-A
BXL-A

BATTERY CAPACITY TESTER ( BLU100A)

 

  • weight – 12,8 kg (28 lb)
  • discharge power – up to 14,2 kW
  • discharge current – up to 160 A
  • applicable to 5,25 – 300 V DC battery voltages
 
BATTERY CAPACITY TESTER ( BLU200A)
  • eight – 14,5 kg (32 lbs)
  • discharge power – up to 19,7 kW
  • discharge current – up to 240 A
  • applicable to 5,25 – 300 V DC battery voltages
 
BATTERY CAPACITY TESTER ( BLU200C)
  • Real-time test parameters monitoring on 7 inch
    touch screen display
  • weight – 14,5 kg (32 lbs)
  • discharge power/current – up to 19,7 kW/240 A
  • applicable to 5,25 – 300 V DC battery voltages
 
BATTERY CAPACITY TESTER ( BLU340A)
  • weight – 20,6 kg (45.4 lb)
  • discharge power – up to 28,4 kW
  • discharge current – up to 160 A
  • applicable to 5,25 – 300 V DC battery voltages
 
BATTERY CAPACITY TESTER ( BLU110T)
  • weight – 12,8 kg (28.2 lb)
  • discharge power – up to 8,5 kW
  • discharge current – up to 150 A
  • applicable to 5,25 – 70,5 V DC battery voltages
 
BATTERY CAPACITY TESTER ( BLU220T)
  • weight – 15,1 kg (33 lb)
  • discharge power – up to 19,2 kW
  • discharge current – up to 340 A
  • applicable to 5,25 – 70,5 V DC battery voltages
 
BATTERY CAPACITY TESTER ( BLU360V)
  • weight – 20,6 kg (45.4 lb)
  • discharge power – up to 28,4 kW
  • discharge current – up to 160 A
  • applicable to 5,25 – 500 V DC battery voltages
 

BLU360V
BLU360V
BLU220T
BLU220T
BLU110T
BLU110T
BLU340A
BLU340A
Battery Resistance Tester (IBAR)

DV Power battery resistance tester – IBAR is portable accurate and very quick resistance tester which determines the state of health of batteries by taking measurements of important battery parameters such as cell internal resistance, cell voltage as well as inter-cell connection resistance.

It is ideal testing tool for maintenance, troubleshooting and performance tests on individual stationary batteries and battery packs in critical backup energy solutions. Device gives a Pass/Warning/Fail indication. All the measurements can be saved in the devices internal memory for later analysis.

Using DV-B Win software it is possible to download results from devices internal memory to a PC and to generate graphical reports for historical trending and further analysis.

IBAR
IBAR
BVR Series ( BVR11)
  • Cell voltage measurement
  • String voltage measurement
  • Ambient temperature measurement
  • Voltage measurement range (cell/ string voltage ± 30 V DC/ ± 500 V DC)
  • Usb communication with PC
  • Bluetooth communication with PC
BVR Series ( BVR20)

  • Cell voltage measurement
  • Ambient temperature measurement
  • Electrolyte temperature measurement
  • Voltage measurement range (cell voltage ± 2,35 V DC ,± 7 V DC, ± 30 V DC)
  • Usb communication with PC
  • RFID string recognation
  • Communication with external density meter
BVR Series ( BVR22)

  • Cell voltage measurement
  • String voltage measurement
  • Ambient temperature measurement
  • Electrolyte temperature measurement
  • Voltage measurement range (intercell voltage/current ± 30 mV DC ,± 300 mV DC, ± 1 V DC Cell / String voltage ± 3 V DV, ±30 V DV, ±600 V DV )
  • Current measurement
  • Usb communication with PC
  • Bluetooth communication with PC
  • RFID string recognation
  • Communication with external density meter


BVR22
BVR22
BVR20
BVR20
BVR11
BVR11
Battery Voltage Supervisor (BVS)

The BVS is an integrated system consisting of:

  • BVS Control Unit (BVS-CU)
  • Cell Voltage Modules (CVM)
  • String Voltage module (SVM) (optional)
  • String current module (SCM) (optional)

The system of Battery voltage supervisor identifies a potential battery malfunction. That is done by monitoring the following cell parameters from an array of the cell voltage modules CVM:

  • Cell voltage
  • Intercell connection voltage
BVS
BVS
Switch To Desktop Version